Economical laboratory single/double stage RO water purifier system, meet general chemical analysis, laboratory equipment washing, cleaning, conventional water for testing center, pure water for autoclave.
Specification
Model
Moro210s/ 220s/ 230s
Moro210d/ 220d/ 230d
Process
Single pass RO system
Double pass RO system
Output of pure water
≥10L/H
≥10L/H
Flow rate (with pure water tank)
≥1-1.5L/min
≥1-1.5L/min
Conductivity at 25℃
≤10μs/cm
≤5μs/cm
PH
5.0-7.5
5.0-7.5
Oxidizabes (as O)
≤0.4mg/L
≤0.4mg/L
Evaporation residue
≤2.0mg/L
≤2.0mg/L
Electrical requirements
220V (230V, 240V) 50Hz
Power
≥100W
≥150W
Dimension (L/W/H)
340*550*530mm
340*550*530mm
Weight
≥30KG
≥35KG
Tank capacity
210s/210d (3 Gallon pressure tank)220s/220d (6.5 Gallon pressure tank) 230s/230d (10 Gallon pressure tank)
Note: The model end with ‘s’ has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm
Product FeaturesIntegrated tabletop water purifier for Type III water.Pure deionized/distilled water.Built-in RO membrane anti-scaling program, RO membrane cleaning manual button.Easy to clean, disinfect and discharge waste water.Conductivity is displayed on the LED screen.Variable outlet capacity from 5LPH to 100LPH.
Lab Test and Corresponding Water Type List
Test Name
Type III Water
Type II Water
Type I Water
Lab glassware washing
√
Hydroponics
√
Sterilizer use water
√
Gas generator use water
√
√
Conventional test
√
Reagents/ drugs preparation, dilution
√
Feed water for ultrapure water
√
IC
√
LC/LC-MS
√
HPLC
√
AAS
√
ICP/ICP-MS
√
GC/GC-MS
√
Trace analysis
√
TOC analysis
√
Organic analysis
√
Inorganic analysis
√
Environmental analytical test
√
Microelectronics parts cleaning
√
Precision instrument use water
√
Analytical reagent/ drugs preparation, dilution
√
Mass spectrometry
√
PCR application/analysis
√
DNA/RNA research
√
Proteomics research
√
Plant and animal cell culture
√
Toxicity analysis
√
Microbiology experiment
√
Immunological experiment
√
Biochemistry experiment
√
Serum test
√
IVF
√
Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)
No.
Name
Specification
Lifespan
1
PP filter
1st stage, 10”/20” (5μm)
3-6 months
2
Activated Carbon filter
2nd stage, 10”/20”
6-12 months
3
Softener filter
3rd stage, 10”/20”
6-12 months
4
Precision filter
4th stage, 10”/20” (1μm)
10-12 months
5
RO membrane
75g/300g
1-2 years
6
Ultra purification resin column
1 year
7
Micro filter
0.22μm
1 year
8
UV lamp
185/254nm
8000 hours
9
Pure water tank
30L, 80L, 120L
Tips: How to avoid damage to reverse osmosis (RO) membrane?There are many situations that cause reverse osmosis membrane damage. In the daily experiment process, laboratory personnel do not pay much attention to the use of equipment, so the service life of the ultrapure water system is also shortened. What should be paid attention to in daily use?1. Raw water qualityThe water used in the laboratory is mostly tap water, and the quality of the water source varies from region to region. The macromolecular substances in the raw water are not completely removed and pass into the reverse osmosis membrane when they pass through the pre-treatment device of the laboratory purification water system, which easily causes the reverse osmosis membrane to be blocked.2. Improper operationThe residual gas in the purification water system runs under high pressure, and the formation of an air hammer will damage the RO membrane. Therefore, it must be ensured that the remaining air is exhausted under the pressure of 2 to 4 bar, and then the pressure is gradually increased.If the device is turned on repeatedly, it will cause unstable pump pressure and even cause RO membrane breakdown.3. Poor disinfectionIf the RO membrane is used for a long period of time without regular disinfection or good disinfection, it will also cause the membrane to be contaminated with a large number of microorganisms, and long-term accumulation will cause damage to the RO membrane.4. RO membrane pre-treatment filter is not maintained properlyPre-treatment is mainly used to filter large particulate matter, colloids, gas, etc. in water quality, and these materials also cause great damage to RO reverse osmosis. Internally filled activated carbon generally needs to be replaced within 1-3 years, and PP cotton needs to be replaced within 6-12 months.5. Not used for a long timeWhen the ultra-pure water machine is not used for a long time, the RO membrane will dry out, and the filtered impurities will be fixed on the RO membrane. When we use it again, tap water cannot pass through the RO membrane. So even if we don’t use water, we still need to turn on the machine from time to time to clear the inside.