High precision temperature control air cooled chiller machine with high performance and competitive price, 6 ton refrigeration capacity, 2 compressors and the total power of 8 HP, spiral type or tube-in-shell type evaporator for choice, suitable for wide range of industrial applications.
Features
Adopted high quality compressors and pumps to ensure safe & quiet running, power saving and durable service life.
Employed microcomputer with easy operation which can control temperature within 3℃ to 45℃ precisely.
Unique design for condenser and heat-dispersion unit result in excellent heat-exchange effect.
Equiped with electrical current overload protection, high & low pressure switch, electrical timer delay safety device. It will alarm to display faulty while any malfunction occurs.
Built in stainless steel insulated water tank, durable and easy to clean.
Complete safely devices including power reverse phase, power short phase and anti-freeze protection.
Ultra low temperature type of chiller can reach below -60℃.
Parameter List
Model
ATO-LC8A
Cooling Capacity
6 ton
Number of Compressors
2
Compressor Total Power
8 HP
Refrigerant
R22 / R407C (Optional)
Evaporator Type
Spiral type / Tube-in-shell type (Optional)
Condenser Type
Finned
Number of Fan
2
Single Fan power
0.25kW
Number of Cooling Water Inlet/Outlet
1 group
Cooling Water Inlet/Outlet Size
DN40
Water Tank Capacity
145L
Pump Power
1HP
Pump Flow
200L/min
Pump Lifts
13M
Power Supply
3-phase 4-wire AC 208V/60Hz, 220V/60Hz, 240V/60Hz, 380V/50Hz, 400V/50Hz, 415V/50Hz, 480V/60Hz (Optional)
Control Voltage
1-phase AC 220V (L+N)
Total Power
7.3kW
Wires Specifications
4x4mm2
Certification
CE
Dimension
L*W*H=1500*730*1400mm
Net Weight / Gross Weight
350kg / 400kg
Shipping Way of ATO Water Chiller
Just confirm us the shipping way by email when place your order.
1. Ship by Air: The compressed refrigerant inside the chiller is a dangerous item with the possibility of explosion, so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shiping way. After the machine arrives at your destination, you need to add refrigerant by local professionals, the process is as simple as adding refrigerant for ordinary air conditioners.) Delivery time is about 15-30 days.
2. Ship by Sea: The transportation time is longer (about 40-55 days), and there is no need to add refrigerant after the equipment arrives at the destination.
Note:
1. The “cooling capacity” is tested based on: Inlet and outlet water temperature of freezing is 12℃/7℃, and the inlet and outlet water temperature of cooling is 30℃/35℃.
2. Working temperature range: Chilled water temperature range is 5℃-35℃, inlet and outlet water temperature difference is 3℃-8℃, condensation temperature not higher than 35℃.
3. Conversion of units: 1 ton cooling capacity=3024kcal/hr, 1kcal/hr=3.969BTU/hr, 1HP=0.735kW=2580kcal/hr
Water Chiller Structure Diagram
①
Compressor
②
High pressure gauge
③
Condenser
④
Dry filter
⑤
Expansion valve
⑥
Water supply
⑦
Evaporator
⑧
Low pressure gauge
⑨
Water tank
⑩
Drain
⑪
Refrigerated water
⑫
Pump
Tips: 4 reasons for noise of industrial water chiller
1. Compressor noise
In the internal structure of the precision water chiller, the compressor is the core position of the chiller. Generally speaking, the compressor has two types: Scroll type and screw type. Once the compressor makes noise, first check whether the expansion valve is excessively opened, and then adjust it a little bit when it is opened. Next, check whether there is too much refrigerant. If it exceeds the limited range, remember to eliminate the redundant refrigeration agent.
2. Noise of water pump
Once the water pump makes noise, it is basically that the water quality is in question. The water quality shall be treated according to the requirements of the corresponding chiller.
3. Lack of lubrication for accessories
Most of the water chiller configurations are made of metal. Once the parts are lack of lubrication, there will be some friction and noise. In addition, we should also pay attention to maintenance at ordinary times, so that there will be fewer failures.
4. Overload and oil shortage
Once there is noise, check whether the compressor is short of oil. If it is found out, make up the oil immediately. Check the load of the compressor in time. If there is any problem, solve it in time.